Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 168
Filtrar
1.
BMC Pulm Med ; 23(1): 213, 2023 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-37330482

RESUMO

BACKGROUND: Mitochondrial dysfunction results in poor organ quality, negatively affecting the outcomes of lung transplantation. Whether hydrogen benefits mitochondrial function in cold-preserved donors remain unclear. The present study assessed the effect of hydrogen on mitochondrial dysfunction in donor lung injury during cold ischemia phase (CIP) and explored the underlying regulatory mechanism. METHODS: Left donor lungs were inflated using 40% oxygen + 60% nitrogen (O group), or 3% hydrogen + 40% oxygen + 57% nitrogen (H group). Donor lungs were deflated in the control group and were harvested immediately after perfusion in the sham group (n = 10). Inflammation, oxidative stress, apoptosis, histological changes, mitochondrial energy metabolism, and mitochondrial structure and function were assessed. The expression of nuclear factor erythroid 2-related factor 2 (Nrf2) and heme oxygenase-1 (HO-1) were also analyzed. RESULTS: Compared with the sham group, inflammatory response, oxidative stress, histopathological changes, and mitochondrial damage were severe in the other three groups. However, these injury indexes were remarkably decreased in O and H groups, with increased Nrf2 and HO-1 levels, elevated mitochondrial biosynthesis, inhibition of anaerobic glycolysis and restored mitochondrial structure and function compared with the control group. Moreover, inflation using hydrogen contributed to stronger protection against mitochondrial dysfunction and higher levels of Nrf2 and HO-1 when comparing with O group. CONCLUSIONS: Lung inflation using hydrogen during CIP may improve donor lung quality by mitigating mitochondrial structural anomalies, enhancing mitochondrial function, and alleviating oxidative stress, inflammation, and apoptosis, which may be achieved through activation of the Nrf2/HO-1 pathway.


Assuntos
Isquemia Fria , Traumatismo por Reperfusão , Humanos , Isquemia Fria/métodos , Hidrogênio/farmacologia , Fator 2 Relacionado a NF-E2/metabolismo , Pulmão/patologia , Estresse Oxidativo , Heme Oxigenase-1 , Oxigênio/metabolismo , Apoptose , Inflamação/metabolismo
2.
HPB (Oxford) ; 25(5): 543-555, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36858919

RESUMO

BACKGROUND: Split liver transplantation permits the transplant of two recipients using a single donor liver. Liver splitting can be performed using the ex-vivo technique (more convenient), or the in-situ technique (shorter cold ischaemic time). We aimed to develop a technique for liver splitting during normothermic machine perfusion which combines the advantages of both techniques and permits graft assessment prior to transplant. METHODS: Human livers declined for transplantation were perfused at 36 °C using a modified-commercial perfusion machine. We developed a six-step method to split whole livers into left lateral segment grafts and extended right grafts. Both partial livers were then perfused on separate machines for individual assessment. RESULTS: Using our technique, 10 whole livers were successfully split during normothermic perfusion resulting in 20 partial grafts. Apart from a single graft which failed due to a technical error, all grafts survived for 24-h after splitting. Survival was demonstrated by lactate clearance, bile production and synthesis of coagulation factors. CONCLUSIONS: Liver splitting during normothermic machine perfusion has the potential to revolutionise split liver transplantation. We describe a novel technique that reliably achieves two grafts from a single donor liver. This raises the possibility of semi-elective transplantation, and sophisticated graft assessment prior to implant.


Assuntos
Transplante de Fígado , Humanos , Transplante de Fígado/métodos , Doadores Vivos , Fígado/cirurgia , Isquemia Fria/métodos , Perfusão/métodos
3.
Liver Transpl ; 28(7): 1173-1185, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35100468

RESUMO

The combined approach of ex situ normothermic machine perfusion (NMP) and nanotechnology represents a strategy to mitigate ischemia/reperfusion injury in liver transplantation (LT). We evaluated the uptake, distribution, and efficacy of antioxidant cerium oxide nanoparticles (nanoceria) during normothermic perfusion of discarded human livers. A total of 9 discarded human liver grafts were randomized in 2 groups and underwent 4 h of NMP: 5 grafts were treated with nanoceria conjugated with albumin (Alb-NC; 50 µg/ml) and compared with 4 untreated grafts. The intracellular uptake of nanoceria was analyzed by electron microscopy (EM) and inductively coupled plasma-mass spectrometry (ICP-MS). The antioxidant activity of Alb-NC was assayed in liver biopsies by glutathione (GSH), superoxide dismutase (SOD) and catalase (CAT) assay, telomere length, and 4977-bp common mitochondrial DNA deletion (mtDNA4977 deletion). The cytokine profile was evaluated in perfusate samples. EM and ICP-MS confirmed Alb-NC internalization, rescue of mitochondrial phenotype, decrease of lipid droplet peroxidation, and lipofuscin granules in the treated grafts. Alb-NC exerted an antioxidant activity by increasing GSH levels (percentage change: +94% ± 25%; p = 0.01), SOD (+17% ± 4%; p = 0.02), and CAT activity (51% ± 23%; p = 0.03), reducing the occurrence of mtDNA4977 deletion (-67.2% ± 11%; p = 0.03), but did not affect cytokine release. Alb-NC during ex situ perfusion decreased oxidative stress, upregulating graft antioxidant defense. They could be a tool to improve quality grafts during NMP and represent an antioxidant strategy aimed at protecting the graft against reperfusion injury during LT.


Assuntos
Transplante de Fígado , Nanopartículas , Traumatismo por Reperfusão , Antioxidantes , Cério , Isquemia Fria/métodos , Citocinas , DNA Mitocondrial , Humanos , Fígado/patologia , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Preservação de Órgãos/métodos , Perfusão/métodos , Projetos Piloto , Traumatismo por Reperfusão/etiologia , Traumatismo por Reperfusão/patologia , Traumatismo por Reperfusão/prevenção & controle , Superóxido Dismutase
4.
Artif Organs ; 46(4): 597-605, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34951495

RESUMO

BACKGROUND: M101 is an extracellular hemoglobin isolated from a marine lugworm and is present in the medical device HEMO2 life®. The clinical investigation OXYOP was a paired kidney analysis (n = 60) designed to evaluate the safety and performance of HEMO2 life® used as an additive to preservation solution in renal transplantation. The secondary efficacy endpoints showed less delayed graft function (DGF) and better renal function in the HEMO2 life® group but due to the study design cold ischemia time (CIT) was longer in the contralateral kidneys. METHODS: An additional analysis was conducted including OXYOP patients and patients from the ASTRE database (n = 6584) to verify that the decrease in DGF rates observed in the HEMO2 life® group may not be due solely to the shorter CIT but also to HEMO2 life® performance. Kaplan-Meier estimate curves of cumulative probability of achieving a creatinine level below 250 µmol/L were generated and compared in both groups. A Cox model was used to test the effect of the explanatory variables (use of HEMO2 life® and CIT). Finally, a bootstrap strategy was used to randomly select smaller samples of patients and test them for statistical comparison in the ASTRE database. RESULTS: Kaplan-Meier estimate curves confirmed the existence of a relation between DGF and CIT and Cox analysis showed a benefit in the HEMO2 life® group regardless of the associated CIT. Boostrap analysis confirmed these results. CONCLUSIONS: The present study suggested that the better recovery of renal function observed among kidneys preserved with HEMO2 life® in the OXYOP study is a therapeutic benefit of this breakthrough innovative medical device.


Assuntos
Isquemia Fria , Transplante de Rim , Isquemia Fria/efeitos adversos , Isquemia Fria/métodos , Função Retardada do Enxerto , Sobrevivência de Enxerto , Hemoglobinas , Humanos , Rim/fisiologia , Transplante de Rim/efeitos adversos , Transplante de Rim/métodos , Estudos Prospectivos , Fatores de Risco
5.
Transplantation ; 106(6): 1193-1200, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34495016

RESUMO

BACKGROUND: Traditional liver transplant strategies with cold preservation usually result in ischemia-reperfusion injury (IRI) to the donor liver. Regular normothermic machine perfusion (NMP) donor livers suffer IRI twice. Here, we aimed to introduce a novel technique called continuous NMP without recooling to avoid a second IRI and its application in livers from extended criteria donors. METHODS: Seven donor livers transplanted following continuous NMP without recooling, 7 donor livers transplanted following standard NMP, and 14 livers under static cold storage (SCS) were included in this study. Perioperative outcomes were recorded and analyzed between groups. RESULTS: During the NMP without a recooling procedure, all livers cleared lactate quickly to normal levels in a median time of 100 min (interquartile range, 60-180) and remained stable until the end of perfusion. In the NMP without recooling and standard NMP groups, posttransplant peak aspartate aminotransferase and alanine aminotransferase levels were both significantly lower than those in the SCS group (P = 0.0015 and 0.016, respectively). The occurrence rate of early allograft dysfunction was significantly lower in the NMP without recooling group than in the SCS group (P = 0.022), whereas there was no difference in the NMP group with or without recooling (P = 0.462). CONCLUSIONS: Our pilot study revealed a novel technique designed to avoid secondary IRI. This novel technique is shown to have at least a comparable effect on the standard NMP, although more data are needed to show its superiority in the future.


Assuntos
Transplante de Fígado , Isquemia Fria/efeitos adversos , Isquemia Fria/métodos , Humanos , Fígado , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Doadores Vivos , Preservação de Órgãos/efeitos adversos , Preservação de Órgãos/métodos , Perfusão/efeitos adversos , Perfusão/métodos , Projetos Piloto
6.
Transplantation ; 106(3): 510-518, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33756546

RESUMO

BACKGROUND: Coagulation factors may inform on liver function during normothermic machine perfusion (NMP). We investigated whether graft ischemic injury impairs the accumulation of anticoagulation factors during NMP of porcine and human livers. METHODS: Dynamics of FV, FVII, FVIII, FIX, and FX during NMP and their correlation with graft injury was investigated in porcine livers with minimal (no warm ischemia, n = 5) or severe injury (60 min warm ischemia, n = 5). Next, FV, FVIII, FIX, fibrinogen, and antithrombin were measured in 35 matched human liver NMPs from the COPE trial. Correlation of these factors with outcomes was explored. Livers were categorized in to 4 groups depending on donor type and posttransplant peak aspartate aminotransferase (AST) as surrogate of minimal (peak < 500 IU/L) or moderate injury (peak > 1000 IU/L). RESULTS: Factor concentrations increased significantly during NMP regardless of severity of injury. In porcine livers, factor concentrations were 2- to 6-fold lower in severely injured grafts (all P < 0.05). All factors negatively correlated with AST (coefficient range: from -0.50 to -0.93; all P < 0.05) and lactate (range: from -0.51 to -0.67; all P < 0.05). In human livers, no difference in factor accumulation rates and no correlation with other markers were observed. One graft with primary nonfunction had low rate of factor accumulation. CONCLUSIONS: Anticoagulation factors accumulate during NMP regardless of donor type and severity of injury. In pigs, severe ischemic injury resulted in significantly lower factor concentrations. In human livers with life-sustaining function, they do not correlate with hepatic injury. Whether low concentrations predict nonfunction in high-risk livers with severe injury requires further investigation.


Assuntos
Transplante de Fígado , Preservação de Órgãos , Animais , Fatores de Coagulação Sanguínea , Isquemia Fria/métodos , Fígado , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Preservação de Órgãos/métodos , Perfusão/efeitos adversos , Perfusão/métodos , Suínos
7.
J Heart Lung Transplant ; 40(11): 1408-1418, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34334301

RESUMO

BACKGROUND: Given the shortage of suitable donor hearts for cardiac transplantation and the growing interest in donation after circulatory death (DCD), our institution recently began procuring cardiac allografts from DCD donors. METHODS: Between October 2020 and March 2021, 15 patients with heart failure underwent cardiac transplantation using DCD allografts. Allografts were procured using a modified extracorporeal membrane oxygenation circuit for thoracic normothermic regional perfusion (TA-NRP) and were subsequently transported using cold static storage. Data collection and analysis were performed with institutional review board approval. RESULTS: The mean age of the DCD donors was 23 ± 7 years and average time on TA-NRP was 56 ± 8 minutes. Total ischemic time was 183 ± 31 minutes and distance from transplant center was 373 ± 203 nautical miles. Recipient age was 55 ± 14 years, with 8 (55.3%) recipients on durable left ventricular assist device support. Post-transplant, 6 (40%) recipients experienced mild left ventricle primary graft dysfunction (PGD-LV), 3 (20%) recipients experienced moderate PGD-LV, and no recipients experienced severe PGD-LV. Postoperative transthoracic echocardiogram demonstrated left ventricular ejection fraction >55% in all recipients. One recipient (6.6%) developed International Society for Heart and Lung Transplantation 2R acute cellular rejection on first biopsy. At last follow-up, all 15 recipients were alive past 30-days. CONCLUSIONS: Cardiac DCD provides an opportunity to increase the availability of donor hearts for transplantation. Utilizing TA-NRP with cold static storage, we have extended the cold ischemic time of DCD allografts to almost 3 hours, allowing for inter-hospital organ transport.


Assuntos
Isquemia Fria/métodos , Rejeição de Enxerto/prevenção & controle , Insuficiência Cardíaca/cirurgia , Transplante de Coração/métodos , Preservação de Órgãos/métodos , Perfusão/métodos , Obtenção de Tecidos e Órgãos/métodos , Adolescente , Adulto , Criança , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Masculino , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
8.
J Heart Lung Transplant ; 40(9): 905-916, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34193360

RESUMO

BACKGROUND: Lung transplantation (LTx) is associated with sterile inflammation, possibly related to the release of damage associated molecular patterns (DAMPs) by injured allograft cells. We have measured cellular damage and the release of DAMPs and cytokines in an experimental model of LTx after cold or warm ischemia and examined the effect of pretreatment with ex-vivo lung perfusion (EVLP). METHODS: Rat lungs were exposed to cold ischemia alone (CI group) or with 3h EVLP (CI-E group), warm ischemia alone (WI group) or with 3 hour EVLP (WI-E group), followed by LTx (2 hour). Bronchoalveolar lavage (BAL) was performed before (right lung) or after (left lung) LTx to measure LDH (marker of cellular injury), the DAMPs HMGB1, IL-33, HSP-70 and S100A8, and the cytokines IL-1ß, IL-6, TNFα, and CXCL-1. Graft oxygenation capacity and static compliance after LTx were also determined. RESULTS: Compared to CI, WI displayed cellular damage and inflammation without any increase of DAMPs after ischemia alone, but with a significant increase of HMGB1 and functional impairment after LTx. EVLP promoted significant inflammation in both cold (CI-E) and warm (WI-E) groups, which was not associated with cell death or DAMP release at the end of EVLP, but with the release of S100A8 after LTx. EVLP reduced graft damage and dysfunction in warm ischemic, but not cold ischemic, lungs. CONCLUSIONS: The pathomechanisms of sterile lung inflammation during LTx are significantly dependent on the conditions. The release of HMGB1 (in the absence of EVLP) and S100A8 (following EVLP) may be important factors in the pathogenesis of LTx.


Assuntos
Isquemia Fria/métodos , Citocinas/metabolismo , Circulação Extracorpórea/métodos , Inflamação/metabolismo , Transplante de Pulmão , Perfusão/métodos , Isquemia Quente/métodos , Animais , Biomarcadores/metabolismo , Líquido da Lavagem Broncoalveolar/química , Modelos Animais de Doenças , Inflamação/etiologia , Pulmão/metabolismo , Preservação de Órgãos/métodos , Ratos , Ratos Sprague-Dawley , Doadores de Tecidos
9.
Sci Rep ; 11(1): 4117, 2021 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-33603011

RESUMO

There is a dearth of effective parameters for selecting potentially transplantable liver grafts from expanded-criteria donors. In this study, we used a nuclear magnetic resonance (NMR) relaxation analyzer-based assay to assess the viability of ex vivo livers obtained via porcine donation after circulatory death (DCD). Ex situ normothermic machine perfusion (NMP) was utilized as a platform for viability test of porcine DCD donor livers. A liver-targeted contrast agent, gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA), was injected into the perfusate during NMP, and the dynamic biliary excretion of the Gd-EOB-DTPA was monitored by measuring the longitudinal relaxation time (T1). The longitudinal relaxation rate (R1) of the bile was served as a parameter. The delay of increase in biliary R1 during early stage of NMP indicated the impaired function of liver grafts in both warm and cold ischemia injury, which was correlated with the change of alanine aminotransferase. The preservative superiority in cold ischemia of dual hypothermic oxygenated machine perfusion could also be verified by assessing biliary R1 and other biochemical parameters. This study allows for the dynamic assessment of the viability of porcine DCD donor livers by combined usage of ex situ NMP and NMR relaxation time based assay, which lays a foundation for further clinical application.


Assuntos
Fígado/patologia , Traumatismo por Reperfusão/patologia , Transplantes/patologia , Animais , Sistema Biliar/metabolismo , Sistema Biliar/patologia , Isquemia Fria/métodos , Fígado/metabolismo , Transplante de Fígado/métodos , Espectroscopia de Ressonância Magnética/métodos , Preservação de Órgãos/métodos , Oxigênio/metabolismo , Perfusão/métodos , Suínos , Doadores de Tecidos , Transplantes/metabolismo , Isquemia Quente/métodos
10.
Int J Mol Sci ; 22(2)2021 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-33419219

RESUMO

The clinical results of lung transplantation (LTx) are still less favorable than other solid organ transplants in both the early and long term. The fragility of the lungs limits the procurement rate and can favor the occurrence of ischemia-reperfusion injury (IRI). Ex vivo lung perfusion (EVLP) with Steen SolutionTM (SS) aims to address problems, and the implementation of EVLP to alleviate the activation of IRI-mediated processes has been achieved using mesenchymal stromal/stem cell (MSC)-based treatments. In this study, we investigated the paracrine effects of human amnion-derived MSCs (hAMSCs) in an in vitro model of lung IRI that includes cold ischemia and normothermic EVLP. We found that SS enriched by a hAMSC-conditioned medium (hAMSC-CM) preserved the viability and delayed the apoptosis of alveolar epithelial cells (A549) through the downregulation of inflammatory factors and the upregulation of antiapoptotic factors. These effects were more evident using the CM of 3D hAMSC cultures, which contained an increased amount of immunosuppressive and growth factors compared to both 2D cultures and encapsulated-hAMSCs. To conclude, we demonstrated an in vitro model of lung IRI and provided evidence that a hAMSC-CM attenuated IRI effects by improving the efficacy of EVLP, leading to strategies for a potential implementation of this technique.


Assuntos
Células Epiteliais Alveolares/efeitos dos fármacos , Isquemia Fria/métodos , Meios de Cultivo Condicionados/farmacologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Traumatismo por Reperfusão/tratamento farmacológico , Células A549 , Células Epiteliais Alveolares/metabolismo , Âmnio/citologia , Apoptose/efeitos dos fármacos , Apoptose/genética , Ciclo Celular/efeitos dos fármacos , Ciclo Celular/genética , Diferenciação Celular/efeitos dos fármacos , Diferenciação Celular/genética , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/genética , Células Cultivadas , Citocinas/genética , Regulação da Expressão Gênica/efeitos dos fármacos , Humanos , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , NF-kappa B/genética , Traumatismo por Reperfusão/fisiopatologia
11.
Artif Organs ; 45(5): 516-523, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33210745

RESUMO

In deceased donor kidney transplantation (KT), a prolonged cold ischemia time (CIT) is a negative prognostic factor for KT outcome, and the efficacy of hypothermic machine perfusion (HMP) in prolonging CIT without any additional hazard is highly debated. We conducted a retrospective study on a cohort of 154 single graft deceased donor KTs, in which a delayed HMP, after a preliminary period of static cold storage (SCS), was used to prolong CIT for logistic reasons. Primary outcomes were postoperative complications as well as 1 year graft survival and function. 73 cases (47.4%) were managed with HMP and planned KT, while 81 (52.6%) with SCS and urgent KT. The median CIT in HMP group and SCS group was 29 hour:57 minutes [27-31 hour:45 minutes] and 11 hour:25 minutes [9-14 hour:30 minutes], respectively (P < .001). The period of SCS in the HMP group was significantly shorter than in the SCS group (10 vs. 11 hour:25 minutes, P = .02) as well as the prevalence of expanded criteria donors was significantly higher (43.8% vs. 18.5%, P < .01). After propensity score matching for these two baseline characteristics, the HMP and SCS groups showed comparable outcomes in terms of delayed graft function, vascular, and urologic complications, infections, and episodes of graft rejection. At 1 year follow-up, serum creatinine levels were comparable between the groups. Therefore, the use of HMP to prolong the CIT and convert KT into a planned procedure seemed to have an adequate safety profile, with outcomes comparable to KT managed as an urgent procedure and a CIT nearly three time shorter.


Assuntos
Isquemia Fria/métodos , Transplante de Rim/efeitos adversos , Preservação de Órgãos/métodos , Perfusão/métodos , Complicações Pós-Operatórias/epidemiologia , Idoso , Aloenxertos/irrigação sanguínea , Isquemia Fria/efeitos adversos , Função Retardada do Enxerto/epidemiologia , Função Retardada do Enxerto/prevenção & controle , Feminino , Rejeição de Enxerto/epidemiologia , Rejeição de Enxerto/prevenção & controle , Sobrevivência de Enxerto , Humanos , Rim/irrigação sanguínea , Transplante de Rim/métodos , Masculino , Pessoa de Meia-Idade , Preservação de Órgãos/instrumentação , Perfusão/instrumentação , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
12.
Life Sci ; 268: 118820, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33278393

RESUMO

INTRODUCTION: Ischemia-reperfusion (I/R) injury causes present challenges in the field of graft transplantation which is also a major contributor to early graft dysfunction or failure after organ transplantation. The study focuses on the effects of prolonged cold-ischemia (CI) on the autophagic activity in the graft lung in a rat orthotopic lung transplantation model. MATERIAL AND METHODS: Donor lungs were preserved under CI conditions for different periods. An orthotopic lung transplantation model was developed, and the lung tissues from donor lungs subjected to CI preservation and reperfusion were harvested. We evaluated the effects of different CI periods on autophagy, reactive oxygen species (ROS) and glucose consumption. Additionally, the mechanism by which prolonged CI affected autophagy was investigated through determination of the molecules related to the mTOR pathway after treatment with 3-Methyladenine (3-MA), rapamycin and an adenosine triphosphate (ATP) synthase inhibitor oligomycin (OM). RESULTS: Prolonged CI led to increased activities of key glycolytic enzymes, glucose consumption and lactic acid production. Autophagy, ROS and glucose consumption were induced in the graft lung after I/R, which reached peak levels after 6 h and was gradually decreased. Most importantly, the perfusion treatment of 3-MA or OM decreased ROS level and autophagy, but increased the extent of mTOR phosphorylation, while the perfusion treatment of rapamycin induced ROS and autophagy. CONCLUSION: Taken together, autophagy mediated by a prolonged CI preservation affects the glucose consumption and ROS production in the graft lung via the mTOR signaling pathway.


Assuntos
Autofagia/fisiologia , Isquemia Fria/efeitos adversos , Transplante de Pulmão/métodos , Pulmão/patologia , Adenina/análogos & derivados , Adenina/farmacologia , Animais , Isquemia Fria/métodos , Glicólise , Pulmão/efeitos dos fármacos , Pulmão/metabolismo , Transplante de Pulmão/efeitos adversos , Masculino , Mitocôndrias/patologia , Oligomicinas/farmacologia , Preservação de Órgãos/efeitos adversos , Preservação de Órgãos/métodos , Fosforilação Oxidativa , Perfusão , Ratos Sprague-Dawley , Espécies Reativas de Oxigênio/metabolismo , Traumatismo por Reperfusão/etiologia , Traumatismo por Reperfusão/patologia , Serina-Treonina Quinases TOR/metabolismo
13.
Transplant Proc ; 53(2): 661-664, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33139037

RESUMO

OBJECTIVE: This study aimed to evaluate how cold ischemia time (CIT) interferes with liver graft function in the first 7 days after surgery for Custodiol (HTK) preserved organs. METHODS: This retrospective observational study analyzed the medical records of 38 transplantation patients at Hospital Leforte Liberdade, São Paulo, in 2018. The study population was divided into 2 groups (group A, CIT < 8 hours; group B, CIT > 8 hours). Postoperative parameters-such as international normalized ratio, total bilirubin, aspartate aminotransferase/alanine aminotransferase, alkaline phosphatase, gamma glutamyl transferase (GGT), lactate dehydrogenase, lactate, creatinine, red blood cell transfusion, need for hemodialysis, use of vasoactive drugs, endotracheal intubation time, length of stay in the intensive care unit (ICU), and length of hospital stay-were compared. RESULTS: Group A (CIT < 8 hours) presented less need for red blood cell transfusions (odds ratio 0.29; confidence interval 0.06-0.98; P = .04), had a shorter hospital stay (P = .024), and had lower levels of total bilirubin (P = .05) and GGT (P = .05) in the first 7 postoperative days. The other variables showed no statistically significant difference. CONCLUSION: In livers preserved with Custodiol, CIT > 8 hours generated higher levels of total bilirubin and GGT in the postoperative period, in addition to higher hospital costs; greater need for red blood cell transfusions; and longer hospitalization, including longer stays in the ICU.


Assuntos
Isquemia Fria/métodos , Transplante de Fígado/métodos , Soluções para Preservação de Órgãos/farmacologia , Preservação de Órgãos/métodos , Feminino , Glucose/farmacologia , Humanos , Masculino , Manitol/farmacologia , Pessoa de Meia-Idade , Preservação de Órgãos/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Cloreto de Potássio/farmacologia , Procaína/farmacologia , Traumatismo por Reperfusão/etiologia , Estudos Retrospectivos
14.
Sci Rep ; 10(1): 22272, 2020 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-33335249

RESUMO

Kidney injury during donation after circulatory determination of death (DCDD) includes warm ischemic (WI) injury from around the time of asystole, and cold ischemic (CI) injury during cold preservation. We have previously shown that Matrix Metalloproteinases (MMPs) are involved in CI injury and that Doxycycline (Doxy), an antibiotic and known MMP inhibitor, protects the transplant kidney during CI. The purpose of our study was to determine if Doxy given before asystole can also prevent injury during WI. A rat model of DCDD was used, including Control, Preemptive Doxy (45 mg/kg iv), and Preemptive and Perfusion (100 microM) Doxy groups. Thirty minutes after asystole, both kidneys were removed. The left kidney was perfused at 4 °C for 22 h, whereas the right was used to establish the degree of warm ischemic injury prior to cold preservation. MMP-2 in the perfusate was significantly reduced in both treatment groups [Control 43.7 ± 7.2 arbitrary units, versus Preemptive Doxy group 23.2 ± 5.5 (p = 0.03), and 'Preemptive and Perfusion' group 18.0 ± 5.6 (p = 0.02)]. Reductions in NGAL, LDH, and MMP-9 were also seen. Electron microscopy showed a marked reduction in mitochondrial injury scores in the treatment groups. Pre-arrest Doxy was associated with a reduction in injury markers and morphologic changes. Doxy may be a simple and safe means of protecting transplant kidneys from both WI and CI.


Assuntos
Injúria Renal Aguda/tratamento farmacológico , Doxiciclina/farmacologia , Transplante de Rim/efeitos adversos , Metaloproteinases da Matriz/genética , Injúria Renal Aguda/metabolismo , Injúria Renal Aguda/patologia , Animais , Isquemia Fria/métodos , Modelos Animais de Doenças , Humanos , Lipocalina-2/genética , Metaloproteinase 2 da Matriz/genética , Metaloproteinase 9 da Matriz/genética , Inibidores de Metaloproteinases de Matriz/farmacologia , Mitocôndrias/metabolismo , Mitocôndrias/patologia , Perfusão/métodos , Ratos , Isquemia Quente/métodos
15.
Ann Surg ; 272(3): 458-466, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32740239

RESUMO

OBJECTIVE: To identify factors that accurately predict 1-year survival for liver transplant recipients with a MELD score ≥40. BACKGROUND: Although transplant is beneficial for patients with the highest acuity (MELD ≥40), mortality in this group is high. Predicting which patients are likely to survive for >1 year would be medically and economically helpful. METHODS: The Scientific Registry of Transplant Recipients database was reviewed to identify adult liver transplant recipients from 2002 through 2016 with MELD score ≥40 at transplant. The relationships between 44 recipient and donor factors and 1-year patient survival were examined using random survival forests methods. Variable importance measures were used to identify the factors with the strongest influence on survival, and partial dependence plots were used to determine the dependence of survival on the target variable while adjusting for all other variables. RESULTS: We identified 5309 liver transplants that met our criteria. The overall 1-year survival of high-acuity patients improved from 69% in 2001 to 87% in 2016. The strongest predictors of death within 1 year of transplant were patient on mechanical ventilator before transplantation, prior liver transplant, older recipient age, older donor age, donation after cardiac death, and longer cold ischemia. CONCLUSIONS: Liver transplant outcomes continue to improve even for patients with high medical acuity. Applying ensemble learning methods to recipient and donor factors available before transplant can predict survival probabilities for future transplant cases. This information can be used to facilitate donor/recipient matching and to improve informed consent.


Assuntos
Isquemia Fria/métodos , Doença Hepática Terminal/cirurgia , Transplante de Fígado/mortalidade , Doadores de Tecidos , Obtenção de Tecidos e Órgãos/métodos , Transplantados , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
16.
Transplantation ; 104(8): 1591-1603, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32732836

RESUMO

BACKGROUND: Combined liver-kidney transplantation (CLKT) improves survival for liver transplant recipients with renal dysfunction; however, the tenuous perioperative hemodynamic and metabolic milieu in high-acuity CLKT recipients increases delayed graft function and kidney allograft failure. We sought to analyze whether delayed KT through pumping would improve kidney outcomes following CLKT. METHODS: A retrospective analysis (University of California Los Angeles [n = 145], Houston Methodist Hospital [n = 79]) was performed in all adults receiving CLKT at 2 high-volume transplant centers from February 2004 to January 2017, and recipients were analyzed for patient and allograft survival as well as renal outcomes following CLKT. RESULTS: A total of 63 patients (28.1%) underwent delayed implantation of pumped kidneys during CLKT (dCLKT) and 161 patients (71.9%) received early implantation of nonpumped kidneys during CLKT (eCLKT). Most recipients were high-acuity with median biologic model of end-stage liver disease (MELD) score of, 35 for dCLKT and 34 for eCLKT (P = ns). Pretransplant, dCLKT had longer intensive care unit stay, were more often intubated, and had greater vasopressor use. Despite this, dCLKT exhibited improved 1-, 3-, and 5-year patient and kidney survival (P = 0.02) and decreased length of stay (P = 0.001), kidney allograft failure (P = 0.012), and dialysis duration (P = 0.031). This reduced kidney allograft futility (death or continued need for hemodialysis within 3 mo posttransplant) for dCLKT (6.3%) compared with eCLKT (19.9%) (P = 0.013). CONCLUSIONS: Delayed implantation of pumped kidneys is associated with improved patient and renal allograft survival and decreased hospital length of stay despite longer kidney cold ischemia. These data should inform the ethical debate as to the futility of performing CLKT in high-acuity recipients.


Assuntos
Doença Hepática Terminal/cirurgia , Rejeição de Enxerto/epidemiologia , Transplante de Rim/efeitos adversos , Transplante de Fígado/efeitos adversos , Preservação de Órgãos/métodos , Idoso , Aloenxertos/imunologia , Aloenxertos/provisão & distribuição , Isquemia Fria/instrumentação , Isquemia Fria/métodos , Isquemia Fria/estatística & dados numéricos , Doença Hepática Terminal/complicações , Estudos de Viabilidade , Feminino , Rejeição de Enxerto/imunologia , Rejeição de Enxerto/prevenção & controle , Sobrevivência de Enxerto/imunologia , Humanos , Rim/imunologia , Transplante de Rim/ética , Transplante de Rim/métodos , Transplante de Rim/estatística & dados numéricos , Transplante de Fígado/ética , Transplante de Fígado/métodos , Transplante de Fígado/estatística & dados numéricos , Masculino , Futilidade Médica/ética , Pessoa de Meia-Idade , Preservação de Órgãos/instrumentação , Preservação de Órgãos/estatística & dados numéricos , Perfusão/instrumentação , Perfusão/métodos , Perfusão/estatística & dados numéricos , Insuficiência Renal/etiologia , Insuficiência Renal/cirurgia , Estudos Retrospectivos , Fatores de Tempo , Tempo para o Tratamento/estatística & dados numéricos , Transplante Homólogo/efeitos adversos , Transplante Homólogo/ética , Transplante Homólogo/métodos , Resultado do Tratamento
17.
Ann Surg ; 272(3): 397-401, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32694447

RESUMO

OBJECTIVE: Normothermic machine perfusion (NMP) enables optimized ex-vivo preservation of a donor liver in a normal physiologic state. The impact of this emerging technology on donor liver utilization has yet to be assessed. SUMMARY BACKGROUND DATA: NMP of the donor liver and ex-vivo enhancement of its function has been envisioned for decades, however only with recent technological advances have devices been suitable for transition to clinical practice. The present study examines the effect NMP on liver utilization in the United States. METHODS: The United Network for Organ Sharing database was queried to identify deceased donor livers procured from 2016 to 2019 (n = 30596). Donor livers were divided by preservation method: standard cold-static preservation (COLD, n = 30,368) versus NMP (n = 228). Donor and recipient risk factors, liver disposition, and discard reasons were analyzed. The primary outcome was liver discard rate between 2 groups. RESULTS: A total of 4037 livers were discarded. The NMP group had a 3.5% discard rate versus 13.3% in the COLD group (P < 0.001), and this was despite NMP donors being older (47.7 vs 39.5 years, P < 0.0001), more frequently donation after cardiac death (DCD) (18% vs 7%, P < 0.001), and having a greater donor risk index (1.6 vs 1.5, P < 0.05). The most common reasons for liver discard in the COLD group were biopsy findings (38%), DCD warm ischemic time (11%), and prolonged preservation time (10%). Survival analysis, following propensity score matching, found no significant difference in 1-year overall survival between recipients of NMP versus COLD livers. CONCLUSIONS: NMP reduces the discard rate of procured livers despite its use in donors traditionally considered of more marginal quality. NMP maintains excellent graft and patient survival. Broader application of NMP technology holds the potential to generate a significant number of additional liver grafts for transplantation every year, thus greatly reducing the nationwide disparity between supply and demand.


Assuntos
Isquemia Fria/métodos , Transplante de Fígado/métodos , Doadores Vivos/provisão & distribuição , Preservação de Órgãos/métodos , Perfusão/métodos , Isquemia Quente/métodos , Adulto , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Estados Unidos
18.
PLoS One ; 15(7): e0235680, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32702005

RESUMO

AIMS: The European Senior Program (ESP) aims to avoid waiting list competition between younger and elderly patients applying for renal transplantation. By listing patients ≥65 years on a separate waiting list and locally allocating of grafts ≥65 years exclusively to this cohort, waiting and cold ischemia times are predicted to be shortened, potentially resulting in improved kidney transplantation outcomes. This study compared a historic cohort of renal transplant recipients being simultaneously listed on the general and the ESP waiting lists with a collective exclusively listed on the ESP list in terms of surrogates of the transplantation outcome. METHODS: Total 151 eligible patients ≥ 65 years from Münster transplant Center, Germany, between 1999 and 2014 were included. Graft function, graft and patient survival were compared using surrogate markers of short- and long-term graft function. Patients were grouped according to their time of transplantation. RESULTS: Recipients and donors in the newESP (nESP) cohort were significantly older (69.6 ± 3.5 years vs 67.1 ± 2 years, p<0.05; 72.0 ± 5.0 years vs 70.3 ± 5.0 years, p = 0.039), had significantly shorter dialysis vintage (19.6 ± 21.7 months vs 60.2 ± 28.1 months, p<0.001) and suffered from significantly more comorbidities (2.2 ± 0.9 vs 1.8 ± 0.8, p = 0.009) than the historic cohort (HC). Five-year death-censored graft survival was better than in the HC, but 5-year graft and patient survival were better in the ESP cohort. After 2005, cold ischemia time between groups was comparable. nESP grafts showed more primary function and significantly better long-term graft function 18 months after transplantation and onwards. CONCLUSION: nESP recipients received significantly older grafts, but experienced significantly shorter time on dialysis. Cold ischemia times were comparable, but graft function in the nESP cohort was significantly better in the long term.


Assuntos
Rejeição de Enxerto/patologia , Sobrevivência de Enxerto , Transplante de Rim , Idoso , Idoso de 80 Anos ou mais , Isquemia Fria/métodos , Comorbidade , Creatinina/sangue , Taxa de Filtração Glomerular , Rejeição de Enxerto/mortalidade , Humanos , Estimativa de Kaplan-Meier , Rim/fisiologia , Masculino , Modelos de Riscos Proporcionais , Diálise Renal , Estudos Retrospectivos , Doadores de Tecidos , Transplante Homólogo
19.
Transplant Proc ; 52(7): 2160-2164, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32430145

RESUMO

BACKGROUND: The cold ischemia time (CIT) is a period of time between harvesting an organ for transplant and its reperfusion just after implantation. CIT may have an impact on frequency of complications after lung transplant that can be treated by means of bronchoscopic intervention. The aim of the study was to investigate the correlation between CIT and frequency of bronchoscopic intervention. METHODS: The retrospective study consists of 91 patients: 22 single lung recipients (24%) and 69 double lung recipients (76%) who underwent lung transplant from March 2012 to June 2019. All statistical analyses were performed in SPSS 25.0 and R 3.5.3. The P levels less than .05 were deemed statistically significant. RESULTS: The average CIT in single lung transplant was 5.91 hours, and in double lung transplant it was 8.61 hours. For the 4- to 8-hour CIT the percentages were 80.95% for single lung recipients and 46.38% for double lung recipients. For CIT longer than 8 hours, the following percentages were observed: 9.53% in single lung transplant and 53.62% in double lung transplant. Each subsequent hour of CIT exponentially increases the risk of intervention 1505 times (50.05%). CONCLUSIONS: Prolonged CIT seems to be a risk factor for airway complication, especially in the double lung recipient group.


Assuntos
Isquemia Fria/efeitos adversos , Isquemia Fria/métodos , Transplante de Pulmão , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Transplantados
20.
Transplant Proc ; 52(7): 2036-2042, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32334797

RESUMO

BACKGROUND: Acid-base balance disorders are a crucial element of ischemia-reperfusion injury during organ transplantation. Hypoxia during organ procurement and storage cause cellular homeostasis imbalance with impact on further graft function. Acidosis in preserved kidney caused by lactate accumulation may have an important role as a common denominator of various pathways leading to cellular damage. METHODS: Our trial sought to answer questions regarding a range of pH alterations in the kidney before the transplantation, their potential cause, and how this may affect further outcome of the kidney transplantation procedure. Perfusion fluid for pH analysis was obtained from perfusion pump (PP) or through kidney flushing at the end of preservation depending on the storage method. RESULTS: A total of 66 sample results were collated with the data from the transplant registry, hospitalization, and outpatient department. Statistical analysis was conducted linking pH results with factors related to donor, recipient, preservation, and outcome according to designed schematics. Mean perfusate pH was significantly lower in simple hypothermia (SH) vs the PP storage group (6.77 vs 7.11; P < .001). All samples of perfusate pH in the SH group were below physiological values (<7.35), and in 10% of samples in the SH group, pH >7.00. CONCLUSIONS: We concluded that kidney storage in cold ischemia is associated with organ acidosis independent of preservation method and that SH is correlated with significantly bigger acidosis than storage in PP, which is an important procedure removing an excessive amount of hydrogen ions from kidney microcirculation, decreasing cell damage.


Assuntos
Desequilíbrio Ácido-Base/etiologia , Isquemia Fria/efeitos adversos , Transplante de Rim , Preservação de Órgãos/efeitos adversos , Perfusão/métodos , Isquemia Fria/métodos , Humanos , Concentração de Íons de Hidrogênio , Transplante de Rim/métodos , Preservação de Órgãos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...